AMS

Experts in Ventilation
Menu
  • Home
  • Products
    • Wall, Window & Ceiling
      • Decor
      • Future
      • Silent
      • Silent 100/200 Design
      • HCM
      • AF
      • HV (Stylvent)
      • CEH
      • HXM
      • HCF
      • CFP
      • SQ / PF / EP
      • HV (Hi-Volume)
      • CF
      • SCP
    • Duct Mounted
      • HIT
      • TD
      • TD Silent
      • TD Silent 1300-2000
      • TD Evo
      • ILT / ILB
      • CSD
      • TDM
      • CVB
      • CAB
      • Cleanpack
      • Mini-Cleanpack
      • SCD
      • SCPP
      • MFB
      • TDE
      • MDB
      • EA/AF
      • BFA
      • APB
      • WJ KIT
      • Powerline Ultra
      • CUD Series
    • Roof Mounted
      • RSS
      • EC
      • RDE / RVE
      • MH / V
      • CTHB / CTVB
      • TH
      • RSC
      • RVF
    • Centrifugal
      • BDB
      • FDA
      • KAT
      • KDD
      • CBT CST CBB CBT
      • CKB
    • People Coolers
      • PW / DF
      • COR
      • HYDOR
      • GSQ
      • JPV
      • Eltastrat Destratifier
    • Noise Control
      • S / P
      • SONEX
      • RT QS
      • RS RT
      • CTS CTL CTU CTZ
      • SBL
      • WLA
      • MFB SIL
      • AERO
      • General Info - Sound
      • Rapid System - Sound
    • Hazardous
      • JV
      • SEAT
      • TD 800/200 EX
      • IFHT
    • Axial Data
  • Ancillaries
    • Grilles
    • Electrical
    • Mounting Units
    • Connecting Units
    • Air Controls
    • Cowls
    • Louvres
  • Downloads
    • Step 1: Register for FindFan program link
    • Step 2: Catalogue / Duct Flow / FindSilencer program
    • Download Training Manual for Sound Attenuation
    • AMS Fan Engineering Manual
    • All Products - PDF Files
  • Info
    • Domestic
    • Motors
    • Installations
    • Roof Units
  • Technical
    • Videos
    • Guidelines
    • Warranty & T and C's
    • Installation
    • Wiring Diagrams
    • Reference Info
    • Trouble shooting
      • Belt-Drives
      • General
      • Mechanical
      • Electrical
      • Dual/Tap Wound Motors
      • Performance
      • Motor Protection
    • Do's and Don'ts
    • Car Park Ventilation
    • Safe Area Smokevent & Hazardous
  • Contact Us
    • Cape Town
    • Johannesburg
    • Durban
    • Port Elizabeth

STAY INFORMED!    Visit the SA Department of Health's website for COVID-19 updates:       www.sacoronavirus.co.za

AMS

Experts in Ventilation
  • Home
  • Products
    • Wall, Window & Ceiling
      • Decor
      • Future
      • Silent
      • Silent 100/200 Design
      • HCM
      • AF
      • HV (Stylvent)
      • CEH
      • HXM
      • HCF
      • CFP
      • SQ / PF / EP
      • HV (Hi-Volume)
      • CF
      • SCP
    • Duct Mounted
      • HIT
      • TD
      • TD Silent
      • TD Silent 1300-2000
      • TD Evo
      • ILT / ILB
      • CSD
      • TDM
      • CVB
      • CAB
      • Cleanpack
      • Mini-Cleanpack
      • SCD
      • SCPP
      • MFB
      • TDE
      • MDB
      • EA/AF
      • BFA
      • APB
      • WJ KIT
      • Powerline Ultra
      • CUD Series
    • Roof Mounted
      • RSS
      • EC
      • RDE / RVE
      • MH / V
      • CTHB / CTVB
      • TH
      • RSC
      • RVF
    • Centrifugal
      • BDB
      • FDA
      • KAT
      • KDD
      • CBT CST CBB CBT
      • CKB
    • People Coolers
      • PW / DF
      • COR
      • HYDOR
      • GSQ
      • JPV
      • Eltastrat Destratifier
    • Noise Control
      • S / P
      • SONEX
      • RT QS
      • RS RT
      • CTS CTL CTU CTZ
      • SBL
      • WLA
      • MFB SIL
      • AERO
      • General Info - Sound
      • Rapid System - Sound
    • Hazardous
      • JV
      • SEAT
      • TD 800/200 EX
      • IFHT
    • Axial Data
  • Ancillaries
    • Grilles
    • Electrical
    • Mounting Units
    • Connecting Units
    • Air Controls
    • Cowls
    • Louvres
  • Downloads
    • Step 1: Register for FindFan program link
    • Step 2: Catalogue / Duct Flow / FindSilencer program
    • Download Training Manual for Sound Attenuation
    • AMS Fan Engineering Manual
    • All Products - PDF Files
  • Info
    • Domestic
    • Motors
    • Installations
    • Roof Units
  • Technical
    • Videos
    • Guidelines
    • Warranty & T and C's
    • Installation
    • Wiring Diagrams
    • Reference Info
    • Trouble shooting
      • Belt-Drives
      • General
      • Mechanical
      • Electrical
      • Dual/Tap Wound Motors
      • Performance
      • Motor Protection
    • Do's and Don'ts
    • Car Park Ventilation
    • Safe Area Smokevent & Hazardous
  • Contact Us
    • Cape Town
    • Johannesburg
    • Durban
    • Port Elizabeth
  • Print
  • Email

Rectangular Duct Attenuators - RT / QS Series

  Features

  • Q-Seal attenuators have an impervious seal between the acoustic fill and ambient air.
  • They are used when no possibility of fibre fly or ambient contamination of the acoustic fill is allowable.
  • Typical applications are as follows: -
          - clean rooms
          - operating theatres
          - wet environments where attenuators are exposed to the elements
          - kitchen exhaust systems
          - applications where workers are sensitive to fibre exposure

  Construction & Testing

  • The complete range of rectangular Q-Seal attenuators have been tested on the Q-Tech insertion loss test rig in full accordance with BS4718:1971.
  • It was found, during testing, that the performance of attenuators of standard construction but with an impervious membrane, was severely degraded.
  • To overcome the degradation and optimise performance, a unique combination of materials was developed to address the problem.
  • The result is a product that is fully supported by testing and, most importantly, with certified results that can be relied upon.

  Performance

Tapered Splitters

Static Insertion Loss, dB
Length Octave Gand Centre Frequency (Hz) Module
Model RT...QS mm 63 125 250 500 1k 2k 4k 8k widths, mm
07A 600 3 5 10 18  20  18  12  9 

275, 550,
825, 1100,
1375, 1650,
1925, 2200

Free Area 27%

07B 900 4  7  14  25  28  25  17  13 
07C 1200 5  10  20  32  38  32  22  16 
07D 1500 7  13  26  40  48  38  27  20 
07E 1800 7  17  31  44  50  42  30  23 
07F 2100 9  19  34  46  51  44  33  25 
07G 2400 10  22  38  49  52  47  35  27 
10A 600 3  5  9  15  17  14  10  8 

300, 600,
900, 1200,
1500, 1800,
2100, 2400 

Free Area 33%

10B 900 4  7  13  22  24  20  14  11 
10C 1200 5  9  17  28  32  25  17  13 
10D 1500 6  12  21  34  40  30  21  15 
10E 1800 7  15  26  39  43  35  24  17 
10F 2100 8  17  29  42  46  38  26  19 
10G 2400 8  19  33  46  48  42  29  20 
12A  600 3 4  8 14  14  12  8  7

 325, 650,
975, 1300,
1625, 1950,
2275

Free Area 38%

12B 900 4 6 11 20 21 17 11 10
12C 1200 4 8 15 26 28 22 15 11
12D 1500 5 10 18 32 35 27 18 12
12E 1800 6 12 22 36 39 32 21 14
12F 2100 7 13 26 40 43 35 23 16
12G  2400  8  15  29  43  46  39  25  18 
15A 600  2  3  7  13  13  10  7  6 

350, 700,
1050, 1400
, 1750, 2100

Free Area 43%

15B 900 3 5 10 18 19 14 10 9
15C 1200 3 6 13 24 25 19 13 10
15D 1500 3 8 17 30 31 24 16 10
15E 1800 4 10 21 34 35 28 18 12
15F 2100 5 12 24 38 39 31 19 14
15G  2400  6  13  27  41  42  34  21  16 
17A 600  2  3  6  11  12  9  6  5 

375, 750,
1125, 1500,
1875, 250 

Free Area 47%

17B 900 3 4 9 16 17 12 8 7
17C 1200 3 6 12 22 22 16 10 7
17D 1500 3 7 16 27 28 20 12 8
17E 1800 3 9 19 32 33 24 14 9
17F 2100 4 10 21 35 36 26 16 10
17G  2400  4  11  24  39  40  29  18  11 
20A 600  1  3  6  10  10  7  5  4 

400, 800,
1200, 1600,
2000, 2400

Free Area 50%

20B 900 2 4 9 15 15 10 7 6
20C 1200 2 5 12 20 19 14 8 6
20D 1500 2 6 15 26 23 18 8 7
20E 1800 3 8 18 30 28 21 11 8
20F 2100 3 9 20 34 32 23 13 9
20G 2400 3 10 22 37 36 25 15 10
22A 600  1  2  5 9  9  6  4  4 

425, 850,
1275, 1700,
2125

Free Area 53%

22B 900 2 3 7 13 13 8 6 5
22C 1200 2 4 10 18 17 12 7 5
22D 1500 2 5 12 23 21 15 7 5
22E 1800 2 6 15 28 26 18 9 6
22F 2100 2 7 18 31 30 20 11 7
22G 2400 3 10 22 37 36 25 15 10
25A 600 1 2 5 8 8 5 3 3

450, 900,
350, 1800,
2250

Free Area 56%

25B 900 1 3 7 12 11 7 5 4
25C 1200 1 4 9 16 15 10 5 4
25D 1500 1 5 11 21 18 13 6 4
25E 1800 2 5 14 26 23 16 8 5
25F 2100 2 6 16 29 27 18 9 6
25G 2400 2 7 18 33 31 20 11 7
 
 
 

  PDF

Download pdf file
 

TDE

TDE

The Multiflow TDE 500 to 710 range consist of fully cased, cylindrical models with circular mounting flanges at both ends and a wired terminal box.

RVF

RVF

The Mini Centrifugal Roof Fan series are the new type roof extract units available in 2 sizes and suitable for vertical and horizontal installation. The low noise external motor and high efficient backward bladed impeller meets the requirement of efficient ventilation in residential, commercial and light industrial applications.

Future 150

Future 150

The Decor Series can be wall or ceiling mounted and is designed to exhaust stale and moist air from bathrooms, toilets, laundries etc. They are also suitable for ventilating all types of small or closed areas.

TD Silent

TD Silent

The Silent Series is a low profile mixed-flow in-line fan that produces low noise when in operation. It does this through a specifically designed perforated internal skin that directs sound waves produced inside the fan to a layer of sound absorbent material.

TD-Evo

NEW!! TD-EVO

The low-profile TD-EVO 250 and 315 in-line mixed-flow fans for circular ducts have a unique design where the support bracket allows the motor and impeller assembly to be fitted or removed without dismantling the adjacent ducting.

History

AMS started trading late in 1994 with Duncan Burl at its helm, ...

More

History

Our Partners

Kruger products are licensed to ...

More

Our Partners

Company Profile

Air Movement Supplies provides a range, backed by ...

More

Profile

Ads

AMS marketing ...

More

Ads

Certificates

ISO, EC etc ....

More

Certificates

News

CTN, JHB & DBN news ...

More

News

© 2022 AMS